YCB8RL-63 RCCB Elektromagnetik
  • Ringkesan produk

  • Detail Produk

  • Ngundhuh data

  • Produk sing gegandhengan

YCB8RL-63 RCCB Elektromagnetik
Gambar
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik
  • YCB8RL-63 RCCB Elektromagnetik

YCB8RL-63 RCCB Elektromagnetik

1. pangayoman kakehan
2. Proteksi sirkuit cendhak
3. Ngontrol
4. Digunakake ing bangunan omah, bangunan non-omah, industri sumber energi lan infrastruktur.
5. Miturut jinis release instan diklasifikasikaké minangka nderek: jinis B(3-5)ln, jinis C(5-10)ln, jinis D(10-20)ln

Hubungi Kita

Detail Produk

YCB8RL-63 RCCB elektromagnetik

Umum

1. Perlindhungan marang efek saka arus fault bumi bolak-balik sinusoidal
2. Perlindhungan marang kontak ora langsung lan pangayoman tambahan marang kontak langsung
3. Perlindhungan marang bebaya geni sing disebabake dening kesalahan insulasi
4. Ngontrol lan Ngalih
5. Digunakake ing bangunan omah, bangunan non-omah, sumber energi, industri lan infrastruktur

Ngeculake

Jinis Data sensitivitas tripping
AC Kanggo arus bolak-balik sinusoidal residual 30mA Kanggo personel, materi lan proteksi geni, uga kanggo pangayoman marang kontak langsung
A Kanggo arus bolak-balik sinusoidal residual lan arus langsung pulsating residual 100mA300mA
Kanggo nyediakake proteksi geni yen ana kesalahan insulasi

Wiring Diagram

Spesifikasi

Jinis Standar lEC/EN 61008-1
Fitur listrik Tipe bocor Tipe elektromagnetik
Rated saiki Ing A 16, 25, 32, 40, 50, 63
Tipe (bentuk gelombang saka bocor bumi sing dirasakake) A, AC
Kutub P 2, 4
Tegangan Rated Ue V 230/400
Tegangan isolasi Ui V 500
Frekuensi dirating Hz 50/60
Rated breaking capacity Inc=I△c A 6000
Rated impuls tahan voltase (1.2/50) Uimp V 6000
Tegangan uji dielektrik ing ind. Frek. kanggo 1 min kV 2.5
Sensitivitas dirating IΔn A 0.03, 0.1, 0.3
Kapasitas nggawe lan breaking residual dirating I△m A 500 (Ing ≤40A); 630(Ing=50A/63A)
Gelar polusi 2
urip listrik t 4000
Fitur mekanik Urip mekanik t 8000
Gelar pangayoman IP20
Suhu panyimpenan -25~+70
Suhu sekitar (kanthi rata-rata saben dina≤35 ℃) -5~+40
Tipe sambungan terminal Kabel / Pin-jinis busbar / U-jinis busbar
Instalasi Ukuran terminal ndhuwur / ngisor kanggo kabel mm2 25
AWG 18-3
Ukuran terminal ndhuwur / ngisor kanggo busbar mm2 10
AWG 18-8
Torsi tightening N*m 2.5
Ing-Ibs 22
Pemasangan Ing rel DIN EN 60715 (35.5mm) kanthi piranti klip cepet
Sambungan Saka ndhuwur lan ngisor

Sakabèhé lan ukuran pemasangan (mm)

 