ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
  • Ringkesan produk

  • Detail Produk

  • Ngundhuh data

  • Produk sing gegandhengan

ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
Gambar
  • ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
  • ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
  • ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
  • ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
  • ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
  • ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
  • ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
  • ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
  • ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
  • ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
  • ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB
  • ZN23-40.5 40.5kv tegangan dhuwur Medium Voltage Indoor Circuit Breaker VCB

ZN23-40.5 40.5kv voltase dhuwur Tegangan Sedheng Ing ...

Pemutus sirkuit vakum ZN23-40.5 MV yaiku piranti distribusi MV njero ruangan saka telung fase AC 50Hz, tegangan 40.5kV, bisa dicocogake karo switchcabinet tipe JYN35 / GBC-35. Cocog kanggo kontrol lan perlindungan ing pembangkit listrik, gardu induk lan sistem distribusi daya, utamane cocok kanggo panggonan operasi sing kerep. Pemutus sirkuit vakum yaiku jinis gerobak, kanthi struktur sing cukup, pangopènan sing trep, aman lan bisa dipercaya.

Hubungi Kita

Detail Produk

● ZN23-40.5 MV vakum sirkuit mbobol iku njero ruangan piranti distribusi MV saka telung phase AC 50Hz, voltase dirating 40.5kV, bisa dicocogake karo JYN35 / GBC-35 jinis ngalih kabinet. Cocog kanggo kontrol lan pangayoman ing pembangkit listrik, gardu lan sistem distribusi daya, utamané cocok kanggo panggonan operasi Kerep. Pemutus sirkuit vakum minangka jinis gerobak, kanthi struktur sing cukup, pangopènan sing trep, panggunaan sing aman lan dipercaya.

Pamilihan

2.1

kahanan operasi

1. Suhu lingkungan: wates ndhuwur +40 ℃, watesan ngisor -15 ℃ (area kadhemen -25 ℃);

2. Altitude: ora luwih saka 2000m;

3. Kelembapan relatif: nilai rata-rata saben dina ora luwih saka 95%, rata-rata saben wulan ora luwih saka 90%;

4. Tekanan uap jenuh: Nilai rata-rata saben dina ora luwih dhuwur tinimbang 2,2 × 10 -3 Mpa, rata-rata saben wulan ora luwih dhuwur tinimbang 1,8 × 10-3 Mpa;

5. Intensitas lindhu ora ngluwihi 8 derajat;

6. Ora ana geni, bledosan, polusi, karat kimia lan panggonan geter abot.

Fitur

1. Struktur sakabèhé saka sirkuit mbobol jinis handcart, nggunakake CT19 utawa mekanisme CD10, bisa dipérang dadi JYN1 lan GBC rong jinis struktur.

2. Awak pemutus sirkuit kasusun saka pigura, insulator, interrupter vakum, spindle lan obah lan krenjang statis. Ing lumahing ngisor pigura dilengkapi 4 wheels, kanggo obah sirkuit mbobol, etc sisih tengen pigura dilengkapi 6 insulator minangka support, tetep obah lan statis support nggunakake, interrupter vakum diinstal antarane dinamis, support statis, pemutus sirkuit nduweni karakteristik volume cilik, struktur prasaja, umur layanan dawa, pangopènan gampang, ora ana bebaya bledosan, ora ana polusi, lsp.

Prinsip operasi

Pemutus sirkuit dilengkapi interrupter vakum medan magnet longitudinal sealing tengah, nalika kontak statis interrupter vakum sing dinamis dipisahake, celah kontak bakal ngasilake busur vakum lan dipateni nalika arus liwat nol. Amarga struktur khusus kontak, longkangan kontak bakal gawé cocok longitudinal Magnetik kolom sak kontak busur, busar seragam mbagekke ing lumahing kontak, ngramut voltase busar kurang, supaya kurang kacepetan karat listrik lan kamar busur karo dhuwur. kekuatan Recovery media busur, nambah mbobol sirkuit short-circuit kemampuan saiki lan urip electrical.

data teknis

Item Unit Paramèter
Parameter voltase, saiki, urip    
voltase dirating kV 40.5
Dirating frekuensi daya wektu cendhak tahan voltase (1 min) kV 95
Rated lightning impulse tahan tegangan (puncak) kV 185
Frekuensi dirating Hz 50
Rated saiki A 1250 1600 2000
Rated short-circuit breaking saiki kA 25 31.5
Rated short-time withstand current (RMS) kA 25 31.5
Rated puncak tahan saiki kA 63 80
Rated short-circuit nutup saiki kA 63 80
Rated single / back-to-back kapasitor bank breaking saiki A 600/400
Dirating short-circuit durasi saiki S 4
Dirating short-circuit saiki breaking kaping kaping 20
Rated urutan operasi   O-0.3s-CO-180s-CO
Resistance bunder galvanik utama μΩ ≤65
Rated voltase operasi   ≌ 220/110
urip mekanik kaping ≥10000
Parameter properti mekanik    
Mbukak reresik antarane kontak mm 22±2
Overtravel mm 6±1
Kontak nutup wektu bouncing ms ≤3
Telung fase, ngoper sinkronisme ms ≤2
kacepetan mbukak rata-rata m/s 1.7±0.2
Kacepetan nutup rata-rata m/s 0,75±0,2
Wektu mbukak (voltase dirating) ms ≤90
Wektu nutup (voltase dirating) ms ≤60
Kekandelan nyandhang sing diidini kanggo kontak dinamis lan statis mm 3

Sakabèhé lan soyo tambah repesukuran (mm)

2,1